Challenge

Customer needs to develop a monitoring system for partial electrical discharge detection in medium voltage lines. The system has to comply with standards to be installed in medium voltage stations.

Solution

Custom design and development of a system that consists of a CoM module and a carrier board. Custom proprietary module is based on Zynq and has been developed in QSeven format. Carrier board has three ADCS JESD-204 80Msps channels and a programmable pulse generator. 

Features
Standards

EN 55022

EN 60255-5

EN 60870-2-1

EN 60870-2-2

EN 60086-1

Communication interfaces

2 USB port

1 GBE port

1 GPS port

1 RS232 port

1 RS485 port